Magauran Iliaca Retractor, 405 mm
The Magauran Iliaca Retractor is a self-retaining retractor that maintains exposure of the surgical site by holding wound or tissue edges apart, freeing the surgical team from continuous manual retraction. The MAGAURAN pattern denotes this specific instrument design within the catalog. It is supplied with a working length of 405 mm. It is applicable to vascular surgery, exposure of the iliac region. Each unit is identified by catalog reference OM187R and is available on a request-a-quote basis for hospitals, surgical centers, distributors, and procurement teams.
2-year warranty
Cubilia vestibulum interdum nisl lorem at interdum posuere libero iaculis.
Free Shipping
Cubilia vestibulum interdum nisl lorem at interdum posuere libero iaculis.
## Overview
The Magauran Iliaca Retractor is a self-retaining retractor that maintains exposure of the surgical site by holding wound or tissue edges apart, freeing the surgical team from continuous manual retraction. Within the Aesculap catalog it is classified under Self-Retaining Retractors in the Self-Retaining Retractors group. The MAGAURAN designation identifies the established pattern of this instrument, allowing procurement teams to specify a consistent, repeatable configuration across orders.
Self-retaining instruments of this kind are valued in the operating room because they hold their position once set, maintaining exposure of the surgical site and reducing the need for a dedicated assistant to provide continuous retraction. This supports a stable, reproducible working field during vascular surgery, exposure of the iliac region.
## Design Characteristics
The listed working length is 405 mm.
The self-retaining mechanism allows the instrument to lock into an open position, so that once the surgeon has established the required exposure the instrument holds that position independently. This characteristic distinguishes self-retaining retractors from hand-held retractors, which require an assistant to maintain force throughout the procedure.
## Technical Specifications
– Pattern: MAGAURAN
– Instrument Type: Iliaca Retractor
– Working Length: 405 mm
## Applications
Based on its instrument type and catalog classification, the Magauran Iliaca Retractor is applicable to vascular surgery, exposure of the iliac region. These applications follow directly from the instrument’s design as a iliaca retractor; uses beyond those supported by the catalog classification are not claimed.
## Identification and Traceability
This product is identified by catalog reference OM187R and registry identifier REG-BV-000177. It is sourced from Aesculap Surgical Instrument Catalog, page 819, under the Mouth Gag, Iliaca Retractor section, preserving full traceability from the catalog to the product record.
## Self-Retaining Mechanism and Clinical Rationale
The defining feature of the Magauran Iliaca Retractor is its self-retaining action. Once the surgeon establishes the required exposure, the instrument locks into an open position and holds that position on its own for the duration of the step. This has two practical consequences in the operating room. First, it removes the need for a dedicated assistant to apply and sustain retraction force, which can free a pair of hands for other tasks at the table. Second, it delivers a steady, reproducible degree of exposure rather than one that varies with an assistant’s fatigue or position. For self-retaining retractors, where a consistent working field supports careful dissection and visualization, a self-retaining design is a common choice. The instrument is set, checked, and adjusted as the procedure requires, and released when exposure is no longer needed.
## Applications in Detail
The Magauran Iliaca Retractor is applicable to the following, each of which follows directly from its classification as a iliaca retractor:
– Vascular surgery: exposure of vessels and surrounding structures during vascular reconstruction.
– Exposure of the iliac region.
These application areas describe where an instrument of this type is used; specific clinical outcomes are not claimed, and any use beyond the catalogued classification is a matter for the operating surgeon’s judgment.
## Handling and Reprocessing Considerations
Instruments in this catalog are reusable surgical instruments. Reusable instruments of this class are typically reprocessed between uses in line with the healthcare facility’s validated cleaning, inspection, and sterilization protocols, and are inspected for correct function of any moving or locking parts before use. Where an instrument incorporates a ratchet, rack, or other self-retaining mechanism, that mechanism is checked to confirm it engages and releases correctly. Specific reprocessing parameters, sterilization methods, and material details are confirmed against the manufacturer’s instructions for use and are not asserted here beyond what the catalog records.
## Ordering Information
The Magauran Iliaca Retractor is offered on a request-a-quote basis. Pricing is not published; hospitals, surgical centers, distributors, and procurement teams are invited to send an inquiry for current availability and quotation. Quantities and any accompanying reprocessing or handling requirements can be confirmed at the time of inquiry.