Hand Fixation Plate (Finger Clamp)
The Hand Fixation Plate (Finger Clamp) is offered as a product family comprising 2 catalogued configurations. It is a hand-positioning and fixation device that stabilizes the hand and fingers to support exposure during hand and extremity procedures. The family provides pattern variants including Hand fixation plate complete with 5 finger clips. It is applicable to hand surgery, extremity procedures. Individual configurations are selectable as variations, each identified by its own catalog reference and available on a request-a-quote basis. Selecting the appropriate configuration allows procurement teams to match the instrument to the specific surgical requirement while maintaining a single, consistent pattern.
2-year warranty
Cubilia vestibulum interdum nisl lorem at interdum posuere libero iaculis.
Free Shipping
Cubilia vestibulum interdum nisl lorem at interdum posuere libero iaculis.
## Overview
The Hand Fixation Plate (Finger Clamp) is a hand-positioning and fixation device that stabilizes the hand and fingers to support exposure during hand and extremity procedures. It is catalogued as a product family under Self-Retaining Retractors in the Hand & Extremity Instruments group and is available in 2 distinct configurations. The configurations in this family share a common instrument design, differing in the specific catalogued attributes described below.
Self-retaining instruments hold their set position during surgery, maintaining exposure of the operative field without continuous manual retraction. Offering the instrument as a family of configurations allows a facility to source a range of sizes and working ends under one pattern, supporting consistency across surgical trays and simplifying replacement and standardization.
## Design Characteristics
Across the family, the catalog lists pattern variants including Hand fixation plate complete with 5 finger clips. These attributes define the differences between the individual configurations and are the basis on which a specific variation is selected.
The self-retaining mechanism allows each instrument in the family to lock into an open position and hold exposure independently once set. This distinguishes the family from hand-held retractors, which require an assistant to sustain retraction throughout the case.
## Configuration Options
The Hand Fixation Plate (Finger Clamp) family includes the following catalogued configurations, each available as a selectable variation:
– Hand fixation plate complete with 5 finger clips (Ref. FO912R)
– to be used with FO912R (Ref. FO913R)
Each configuration is identified by its own catalog reference to ensure that a specific size, tip, or blade selection can be quoted and reordered without ambiguity.
## Technical Specifications
– Instrument Type: Hand Fixation Plate (Finger Clamp)
– Category: Self-Retaining Retractors
– Subcategory: Hand & Extremity Instruments
– Family Reference: REG-BV-000472
– Configuration Count: 2
– Available Variant: Hand fixation plate complete with 5 finger clips
## Applications
Based on its instrument type and catalog classification, the Hand Fixation Plate (Finger Clamp) family is applicable to hand surgery, extremity procedures. These applications follow from the design of the instrument as a hand fixation plate (finger clamp); uses beyond those supported by the catalog classification are not claimed.
## Self-Retaining Mechanism and Clinical Rationale
The defining feature of the Hand Fixation Plate (Finger Clamp) is its self-retaining action. Once the surgeon establishes the required exposure, the instrument locks into an open position and holds that position on its own for the duration of the step. This has two practical consequences in the operating room. First, it removes the need for a dedicated assistant to apply and sustain retraction force, which can free a pair of hands for other tasks at the table. Second, it delivers a steady, reproducible degree of exposure rather than one that varies with an assistant’s fatigue or position. For hand & extremity instruments, where a consistent working field supports careful dissection and visualization, a self-retaining design is a common choice. The instrument is set, checked, and adjusted as the procedure requires, and released when exposure is no longer needed.
## Applications in Detail
The Hand Fixation Plate (Finger Clamp) is applicable to the following, each of which follows directly from its classification as a hand fixation plate (finger clamp):
– Hand surgery: stabilizing the hand to expose the operative field during hand and finger procedures.
– Extremity procedures: exposure during procedures on the upper or lower extremity.
These application areas describe where an instrument of this type is used; specific clinical outcomes are not claimed, and any use beyond the catalogued classification is a matter for the operating surgeon’s judgment.
## Handling and Reprocessing Considerations
Instruments in this catalog are reusable surgical instruments. Reusable instruments of this class are typically reprocessed between uses in line with the healthcare facility’s validated cleaning, inspection, and sterilization protocols, and are inspected for correct function of any moving or locking parts before use. Where an instrument incorporates a ratchet, rack, or other self-retaining mechanism, that mechanism is checked to confirm it engages and releases correctly. Specific reprocessing parameters, sterilization methods, and material details are confirmed against the manufacturer’s instructions for use and are not asserted here beyond what the catalog records.
## Ordering Information
The Hand Fixation Plate (Finger Clamp) is available in multiple configurations. Refer to the individual variations for exact specifications and catalog references. Pricing is not published; the family and its configurations are offered on a request-a-quote basis for hospitals, surgical centers, distributors, and procurement teams. Send an inquiry specifying the required configuration for current availability and quotation.
| Configuration |
Hand fixation plate complete with 5 finger clips ,to be used with FO912R |
|---|