Bowman Double Ended Probe

SKU: REG-001919 Category:

Bowman Double Ended Probe is a double ended probe catalogued in the Probes section of the Aesculap Surgical Instrument Catalog. It is listed under the BOWMAN pattern. The catalog lists the instrument bilingually as Double Ended Probe / Doppelknopfsonde. Every configuration in this listing is printed as length 130 mm, straight, and bulb-headed tip. The family comprises 5 catalogued configurations that differ by diameter. Printed diameters run from 0.7 mm to 1.9 mm. Specifications are reproduced exactly as printed in the source catalog. Submit an inquiry to request a quote or confirm availability.

Select Variation5 options

2-year warranty

Cubilia vestibulum interdum nisl lorem at interdum posuere libero iaculis.

Free Shipping

Cubilia vestibulum interdum nisl lorem at interdum posuere libero iaculis.

## Product Overview

Bowman Double Ended Probe is a double ended probe listed in the Probes range of the Aesculap Surgical Instrument Catalog, page 1392. The catalog identifies the instrument under the BOWMAN pattern, which is the designation procurement teams and distributors use to identify this instrument family across suppliers. The source catalog is bilingual and prints the designation as Double Ended Probe in English and Doppelknopfsonde in German, so either term can be used when matching this item against an existing inventory or tender list. This entry represents the complete catalogued family of 5 configurations rather than a single item, so the specifications below describe the full printed range. Each configuration carries its own catalog number and is quoted separately. The family is printed in the catalog under the range OB510-OB514. It is classified in the catalog under Surgical Instruments > Probes > Double Ended Probe.

## Design Characteristics

The following characteristics are printed for every configuration in this listing: length 130 mm, straight, bulb-headed tip, and length (imperial) 5 1/8″. Overall length is printed as 130 mm (5 1/8″ imperial). The working portion is printed as straight, which is the geometry the catalog specifies for this reference. The tip is printed as bulb-headed tip. The catalog prints these descriptors bilingually: straight (gerade) and bulb-headed tip (Knopfspitze). Characteristics that differ across the family are set out under Configuration Options below.

## Configuration Options

The family is catalogued in 5 configurations. Configurations are distinguished by diameter. Printed diameter options are 0.7 mm, 0.9 mm, 1.4 mm, 1.6 mm, and 1.9 mm. Any combination not listed below is not printed in the source catalog and is therefore not offered as a catalogued configuration.

– **OB510** — straight; bulb-headed tip; length 130 mm; diameter 0.7 mm; second working-end diameter 0.8 mm
– **OB511** — straight; bulb-headed tip; length 130 mm; diameter 0.9 mm; second working-end diameter 1.1 mm
– **OB512** — straight; bulb-headed tip; malleable; length 130 mm; diameter 1.4 mm; second working-end diameter 1.3 mm
– **OB513** — straight; bulb-headed tip; malleable; length 130 mm; diameter 1.6 mm; second working-end diameter 1.5 mm
– **OB514** — straight; bulb-headed tip; malleable; length 130 mm; diameter 1.9 mm; second working-end diameter 1.8 mm

Each configuration above is a separately catalogued item and can be quoted individually or as a set. Where two configurations carry identical printed specifications, the source catalog distinguishes them by catalog number only.

## Technical Specifications

– **Instrument type:** Double Ended Probe
– **Pattern:** BOWMAN
– **Length:** 130 mm
– **Curvature:** straight
– **Tip:** bulb-headed tip
– **Length (imperial):** 5 1/8″
– **Diameter options:** 0.7 mm, 0.9 mm, 1.4 mm, 1.6 mm, and 1.9 mm
– **Catalog category:** Probes (BN)
– **Catalog numbers:** OB510, OB511, OB512, OB513, OB514
– **Configurations:** 5
– **Family ID:** FAM-000033
– **Source:** Aesculap Surgical Instrument Catalog, p. 1392

## Specification Coverage

The source catalog prints overall length, working-end diameter, curvature, and tip form for this listing. It does not print edge, size code, material, working angle, and shaft characteristic; these values are omitted here rather than estimated, and can be confirmed on inquiry. This listing reproduces only what the manufacturer’s catalog states. No material, certification, performance or clinical claim is added.

## Ordering Information

Bowman Double Ended Probe is supplied on a request-for-quote basis; the catalog publishes no price. Quote the catalog number for the configuration required. This family covers OB510, OB511, OB512, OB513, and OB514. Refer to the individual configurations listed above for the exact printed specification of each. Send an inquiry to confirm current availability, packaging and lead time, or to request a formal quotation. Contact us for procurement documentation, including catalog references for tender submissions.

## Source and Traceability

All specifications above are reproduced from the Aesculap Surgical Instrument Catalog, page 1392, Probes section. Registry reference REG-000057; family FAM-000033. Values not printed in the source are omitted rather than estimated. For reference, the printed specification block for OB510 reads: · BOWMAN · 5 1/8“, 130.00 mm · straight, gerade · bulb-headed tip, Knopfspitze

Diameter

0.7 mm

,

0.9 mm

,

1.4 mm

,

1.6 mm

,

1.9 mm

Length

130 mm

Curvature

Straight

Tip

bulb-headed tip

Pattern

BOWMAN