Monopolar Wire Loop Electrode, Straight, 135 mm (5 1/4″), Long Shaft, Ø 4 mm
| Electrosurgical type | Geometry |
Monopolar ,Straight |
|---|---|
| Length | Diameter | Shaft profile |
135 mm (5 1/4") ,4 mm ,Long shaft |
| Working end | Insulation |
Wire loop ,Insulated ,Reusable ,non-sterile |
- Straight monopolar wire loop electrode with an insulated, long-shaft design.
- Overall length of 135 mm (5 1/4″) and a specified diameter of 4 mm.
- Reusable, non-sterile electrode supplied not sterilized ex works.
Monopolar Wire Loop Electrode, Straight, 135 mm (5 1/4″), Long Shaft, Ø 4 mm
| Electrosurgical type | Geometry |
Monopolar ,Straight |
|---|---|
| Length | Diameter | Shaft profile |
135 mm (5 1/4") ,4 mm ,Long shaft |
| Working end | Insulation |
Wire loop ,Insulated ,Reusable ,non-sterile |
- Straight monopolar wire loop electrode with an insulated, long-shaft design.
- Overall length of 135 mm (5 1/4″) and a specified diameter of 4 mm.
- Reusable, non-sterile electrode supplied not sterilized ex works.
2-year warranty
Cubilia vestibulum interdum nisl lorem at interdum posuere libero iaculis.
Free Shipping
Cubilia vestibulum interdum nisl lorem at interdum posuere libero iaculis.
Product Overview
The Monopolar Wire Loop Electrode is an electrosurgical accessory designed for use with compatible monopolar electrosurgical equipment. This model features a straight configuration, an insulated long shaft, and a 135 mm (5 1/4″) overall length. Its specified diameter is 4 mm. It is intended for gynaecological use, with conization of the portio listed as its indication. It is reusable and supplied non-sterile, and is not sterilized ex works.
Design and Application
The straight geometry provides a direct instrument profile, while the long shaft supports access to the working area. The wire loop is the defining working-end configuration. Its stated indication is conization of the portio in gynaecological practice. Confirm 4 mm diameter and connection compatibility with the intended system and inspect the wire loop and insulation before use.
Handling and Care
Before first use and after each subsequent use, follow the manufacturer’s instructions and validated facility procedures for cleaning, rinsing, drying, inspection, and sterilization. Inspect the wire loop for deformation and the shaft and insulation for damage. Do not use if it fails inspection.
Technical Specifications
| Instrument type | Wire loop electrode |
|---|---|
| Electrosurgical type | Monopolar |
| Geometry | Straight |
| Length | 135 mm (5 1/4″) |
| Diameter | 4 mm |
| Shaft profile | Long shaft |
| Insulation | Insulated |
| Discipline | Gynaecology |
| Indication | Conization of the portio |
| Type of sterilization | Not sterilized ex works |
| UDI Direct Marking | No |
| Sterility | Non-sterile |
| Disposable / Reusable | Reusable |
Overall dimensions: 135 mm (5 1/4″)
Design: Straight monopolar wire loop electrode with insulated long shaft
| Electrosurgical type | Geometry |
Monopolar ,Straight |
|---|---|
| Length | Diameter | Shaft profile |
135 mm (5 1/4") ,4 mm ,Long shaft |
| Working end | Insulation |
Wire loop ,Insulated ,Reusable ,non-sterile |
Related products
ATRAUMATA® Monopolar Dissecting Forceps, straight, 200 mm (7 7/8″), jaw width: 2 mm, jaw: toothing DE BAKEY
In stock
BRAUN Uterine Depressor, curved, 270 mm (10 5/8″), double ended, Ø 24 mm, 28 mm
In stock
Electrode Handle, monopolar, straight, 4.50 m, Ø 4 mm, with 2 finger pushbuttons
In stock
KRISTELLER Vaginal Specula, lower and upper blade, 220 mm (8 3/4″), work. length: 110 mm, jaw width: 20 mm
In stock